For hearing assistance, a stage needs a pickup that is as direct and even as possible. Existing individual microphones often provide a good foundation for this. If the ensemble plays without body microphones, a directional main microphone setup can be a suitable starting point. Whether it is sufficient depends on the intelligibility at all important acting positions – not just the microphone model.
Auracast™ transmits the provided sound to compatible receiving devices. This allows the acoustic path through the audience area to be bypassed. However, reverberation and background noise that are already present in the microphone signal are also transmitted.
This article particularly addresses the previously unamplified theatre stage. The auditorium does not necessarily need to become louder; people with hearing impairments should be able to follow the action better.
Why does hearing assistance start at the microphone?
At the microphone, the voice and its reflections from the ceiling, walls, and stage surfaces come together. With greater distance, the direct voice becomes weaker compared to the room sound. More gain then raises both.
Shure explains this in the Guide to Live Microphone Techniques. The critical distance (reverberation radius) refers to the distance at which direct sound and reverberation are equally strong under the respective acoustic conditions. It is not a fixed value in metres for a type of microphone.
The direction the actor is speaking in also matters. DPA shows in Facts about speech intelligibility how the recorded speech spectrum changes with position. A line delivered towards the audience sounds different from the same line with the head turned away. These movements belong in the rehearsal.
A transmission to the ear does not replace a suitable pickup. This also applies to a Summitwave system. If the microphones mostly pick up room sound in the first place, the benefit for hearing assistance remains limited.
Which miking approach suits the stage?
Check existing speech microphones first
If headsets, lapel, or handheld microphones are already in use, their signals should be checked first. The short distance to the voice is an important advantage. Feed playback sources in as directly as possible rather than picking them up again from a loudspeaker.
The Code of Practice for Assistive Listening Systems recommends, in section 8.1, close miking and feeding in the relevant programme signals. The document is a professional guideline, not an Austrian legal regulation.
A main microphone pair for the action on stage
Without individual microphones, a pair of directional small diaphragm microphones is a possible starting point. Together they should capture the relevant action on stage. Position, distance, and orientation are set up as an interconnected system.
Such a pair does not guarantee full coverage of every stage. Quiet dialogues far back or concealed playing areas may require additional measures. For this, closer microphones, spot microphones, or a changed position of the main system may be considered.
Stage-edge and hanging microphones are further tools. Shure's live guide describes both approaches for theatre. Boundary microphones must be tested with steps and props. For suspended microphones, sight lines, stage design, and a properly secured installation also count.
“Boundary” does not automatically mean omnidirectional: there are also directional versions. Form factor and polar pattern are separate selection criteria.
What do cardioid, supercardioid, and hypercardioid do?
The polar pattern describes the sensitivity to sound from different directions. It is not a range specification. A more directional microphone does not reach any further.
- Cardioid: favours sound from the front and rejects sound from the rear most strongly.
- Supercardioid: is narrower at the front but also picks up a small amount from the rear.
- Hypercardioid: is narrower still at the front; its rear lobe is more pronounced.
Shure explains these differences in Specialist Polar Patterns. A loudspeaker directly behind the microphone is therefore not ideal for every pattern. The actual polar diagram and the angles of incidence of unwanted sound sources are crucial.
Directional does not mean deaf at the back. From left: cardioid, supercardioid, hypercardioid. The microphone front faces upwards. The curves show relative sensitivity, not spatial pickup limits.
Own representation based on the models in the SCHOEPS Image Assistant and the explanation from Shure. Idealised, linear magnitude scale; no measurement curves of specific products.
An example is the Schoeps MK 41. The manufacturer refers to it as supercardioid, although in practical jargon “hypercardioid” is also used. Schoeps describes its directivity, which stays comparatively consistent across frequencies, and the attenuation of diffuse room sound. This makes it a possible tool, not a blanket purchase recommendation.
The directional effect applies spatially: An ideally rotationally symmetrical microphone attenuates sound arriving from the sides and correspondingly from above at an angle. However, it does not have an independently adjustable horizontal and vertical pickup area. Orientation and tilt determine where the stage, ceiling, and back are relative to the microphone.
How are position, distance, and angle planned?
First, capture the playing area
A stage plan needs more than the total width. Mark speaking positions, stage depth, possible hanging points, and obscuring scenery. Add ventilation, projectors, speakers, and prominent reflective surfaces.
A pair mounted far in front of the stage can see the entire width but records from a greater distance. Hanging higher creates an overview but does not automatically improve intelligibility. The microphones should capture the relevant sources as directly as possible.
Position and tilt belong together. Blue shows the direct sound path, orange a possible ceiling reflection. The microphone axis is aimed at the person. How much the reflection is attenuated depends on the angle of incidence and the microphone.
Own schematic representation according to Shure's live guide. Not to scale; no mounting recommendation or calculated room acoustics.
Keep three different quantities apart
The base width is the distance between the microphone capsules. The microphone angle is between their axes. The stereo recording angle describes the area of sound sources that is represented between left and right during the intended playback.
The SCHOEPS Image Assistant explains these relationships and simulates various arrangements. A larger recording angle does not automatically make more distant or quieter voices clearer. It describes the spatial representation, not guaranteed speech intelligibility.
Seeing the stage and representing it stereophonically are different tasks. Orange marks the base width; the blue axes form the microphone angle. The grey fan only shows the geometric angle to the stage. It must be aligned with a separately determined stereo recording angle.
Own principle sketch according to SCHOEPS Image Assistant. No calculated stereo arrangement; without predefined distances or adjustment angles.
Check mono from the start
A stereo pair should not be mixed to mono without testing. With spatially separated microphones, time differences can weaken individual frequencies. DPA explains this in Stereo recording techniques and setups.
Check the planned playback with speech from all important positions. If a mono sum is needed, make it an explicit part of the test. Changing distance or arrangement may be more sensible than correcting the sound afterwards.
What setups fit typical stage scenarios?
The following suggestions are starting points for a rehearsal, not finished installation plans. “Budget” and “high-end” refer to different investment classes, not guaranteed improvements in intelligibility. The product types have been verified based on the linked manufacturer documents; the scenario-related selection is our editorial recommendation. As of September 2026.
Compact unamplified stage with a clear view of the ensemble
Microphone type: directional small diaphragm condenser microphones as the main pair. Budget example: RØDE M5 Matched Pair, cardioid. High-end example: SCHOEPS Stereo Set CMC 1 U with MK 41, supercardioid. The SCHOEPS set must explicitly include the MK-41 capsules.
Position: As a starting point, centrally in front of the relevant performance area, above the sight lines and angled towards the speaking individuals. As close as the staging and safe mounting allow. The two axes are aligned to the left and right halves; distance and angle are then coordinated together. Do not point vertically at the ground.
Check: quiet speech at the back and at the edges as well as the centre of the stage in mono. M5 and MK 41 have different characteristics: the same angles do not yield the same setup. Additionally required are suitable mounts, cables, and microphone inputs with appropriate phantom power.
Deep stage or multiple separate performance zones
Microphone type: multiple targeted directional microphones, instead of just one more distant main pair. Budget example: Audio-Technica PRO45, suspended cardioid. High-end example: SCHOEPS CMC 1 U with MK 41, each as a complete microphone consisting of amplifier and capsule.
Position: First, mark the important speaking zones. Aim a microphone in front of and above its area at the head positions there. A rear zone may receive its own closer pickup if necessary. Do not arrange all microphones side by side at the front edge of the stage if the actual problem is depth.
Check: transitions between the zones, shadowing by scenery and overlaps. Only open the channels you need, or pull the others down. Number and height follow from listening tests, not from a fixed rule in metres. The PRO45 has a suspension device; a suitable mounting for SCHOEPS should be planned additionally.
Fixed playing position at the table or near the edge of the stage
Microphone type: boundary condenser microphone on a suitable surface. Budget example: Audio-Technica PRO44, half-cardioid. High-end example: SCHOEPS BLM 03 C with CMC 6, hemispherical. The BLM capsule alone is not a complete microphone.
Position: Flat on a sufficiently large, hard surface near the actual speaking position. With the PRO44, align the front towards the source. Place at the edge of the stage outside of walkways; maintain distance from clattering props on a playing table. Do not place on a small freestanding tripod: The surface is part of the recording principle.
Check: Footfall noise, table sounds and audience contribution. The hemispherical BLM 03 C is not a directional upgrade of the PRO44. It is mainly suitable here in quiet environments and with a nearby source. If audience noise needs to be rejected, I would prefer the directional variant – even over the more expensive example.
Moving performers with quiet dialogues
Microphone type: body-worn condenser microphone near the mouth. Budget example: Samson SE10x, single-ear headset with omnidirectional pattern. High-end example: DPA 6066, headset microphone with omnidirectional pattern.
Position: capsule to the side of the mouth, outside the direct airflow and without skin or costume contact. Adjust the headset and route the cable with strain relief. The distance should remain stable during head movements. The exact capsule position depends on the respective mounting instructions and the wearing test.
Check: whispering, loud passages, hugs and costume changes. Here, the proximity to the voice provides an advantage despite the omnidirectional pattern. Neither example is a complete wireless system: compatible connectors, bodypack transmitters and receivers must be selected separately. For wired operation, a suitable power adapter may be necessary; do not connect directly to any phantom power.
Presenting, readings and audience questions
Microphone type: handheld microphone or the same microphone on a stand. Budget example: Sennheiser e 835, dynamic cardioid. High-end example: Neumann KMS 105, condenser microphone with supercardioid.
Position: in front of the mouth and aimed at it, with as consistent a short speaking distance as possible. On the stand, first adjust to the person, not the other way around. For audience questions, actually bring the microphone to the person asking; a stage microphone does not capture the audience area equally.
Check: lowering the microphone while gesturing, turning the head towards the screen and handling noises. The e 835 does not require phantom power, while the KMS 105 needs a suitable supply. The mentioned models are wired; a wireless solution is a separate system. Even a high-end handheld microphone is not a substitute for picking up a whole area from far away.
How does the recording reach the audience clearly?
A dedicated hearing assistance mix facilitates the balancing of voices, music and playback. The room mix does not necessarily fit, as it complements the already acoustically audible stage sound. All content-relevant sources must arrive in the hearing assistance path.
The Summitwave TX receives the finished mix via a suitable audio output. The TX operating manual describes analogue and Dante inputs. Microphone preamplification, any required phantom power and mixing must fit the setup. Never connect a microphone pair without checking the input specifications.
Microphones solely for hearing assistance do not need to be additionally routed to the room speakers. This prevents a feedback path from being created through these speakers. Other existing loudspeakers can still bleed into the microphones.
Avoid having more microphones open at the same time than necessary. An automatic mixer can help, but must be tested with quiet speech, simultaneous voices and music. Thresholds that are too strict can cut off the start of sentences. Shure's Guide to Audio Processors describes threshold, hold time and attenuation.
What must the rehearsal demonstrate?
Listen through an actual receiver in the audience area. Involve people who will use the service later if possible. Do not only check loud speech from the centre of the stage:
- Quiet dialogues at the front, back, and both edges of the stage.
- Head movements, movement, and speech from behind scenery.
- Footsteps, props, ventilation, and other background noises.
- Music, playback, and simultaneous speaking.
- The intended mono or stereo playback.
- Scene changes, muting, and the listening impression together with the room sound.
Document anomalies by position and scene. Specifically alter microphone placement or mixing and repeat the section. Also determine who checks the hearing assistance path before each performance.
For a measurement-based assessment, IEC 60268-16 defines the Speech Transmission Index (STI). The IEC specifies limits of the procedure, including with digital speech compression. A specialist must therefore choose the appropriate measurement method. A single parameter does not replace practical user testing.
The receiving side remains a separate part of the planning. Our article “Does my smartphone need to support Auracast?” covers it.
Conclusion: A directional main microphone pair can be a good starting point for an unamplified stage. Key factors are recording quality, complete sources, and a tested mix. Two high-quality microphones alone do not make a stage accessible.
For stage and building technicians
Planning hearing assistance for your stage?
Discuss your stage situation with Summitwave. A stage plan, possible microphone positions and typical scenes are helpful.
Book a free demoView system overviewSources
Standard and code of practice
- IEC: IEC 60268-16:2020, corrected version July 2025. Public description of STI and procedural limits; complete standard text not evaluated.
- Audio Industries Committee on Assistive Listening Systems / ISCVE: Code of Practice for the Design and Operation of Assistive Listening Systems, December 2023, particularly sections 8.1–8.2 and 11.3. Specialist guide, no legal requirement.
Microphone techniques and signal processing
- Shure: Microphone Techniques for Live Sound Reinforcement, directional characteristics, room acoustics and theatre.
- Shure: Specialist Polar Patterns: Hypercardioid and Subcardioid, 20.05.2015.
- Shure: BETA 91A – Specification Sheet, example of a directional boundary microphone, no product recommendation for speech.
- SCHOEPS: MK 41, manufacturer description of the supercardioid capsule.
- SCHOEPS: Image Assistant, assistance with directional characteristics, base width, microphone angle and stereo recording angle.
- DPA Microphones, Eddy Bøgh Brixen: Facts about speech intelligibility, speech spectrum and recording position.
- DPA Microphones: Stereo recording techniques and setups, AB, XY and mono compatibility.
- Shure: Selection and Operation of Audio Signal Processors, automatic microphone mixers.
- Summitwave: TX – user manual, audio sources and level control.
Product examples for the scenarios
- RØDE: M5, manufacturer description of the cardioid pair.
- SCHOEPS: Stereo set CMC 1, variant with MK 41; BLM 03 C, directional characteristic, boundary layer and necessary CMC amplifier.
- Audio-Technica: PRO45, suspension and cardioid characteristic; PRO44, half-cardioid and powering.
- Samson: SE10x, carrying method, omnidirectional characteristic and connection options.
- DPA: 6066, headband microphone and connection options.
- Sennheiser: e 835, dynamic cardioid.
- Neumann: KMS 105, condenser microphone, supercardioid and phantom power.
Sources checked and accessed on 30 September 2026. Our planning notes do not replace measurements on your specific stage. Product examples were selected based on documentation, not measured in a comparative Summitwave test.